Search found 3 matches

by finesniper
Fri Jul 28, 2017 1:04 pm
Forum: Other questions
Topic: Current clamp circuit with capacitance compensation
Replies: 3
Views: 3884

Current clamp circuit with capacitance compensation

I am trying to create a current clamp circuit with bridge balance and capacitance neutralization. Luckily I was able to get a version of older demos, including init_r_comp and init_rc_comp3. Further on, my questions will be about init_rc_comp3, as I was unable to fully understand how this circuit wo...
by finesniper
Wed Oct 12, 2016 11:23 am
Forum: Adding new mechanisms and functions to NEURON
Topic: Transient potassium current as leak
Replies: 1
Views: 4450

Transient potassium current as leak

Hi Ted I apologise in advance if my question is being posted in wrong place. My problem concerns a transient potassium current which is extremely low-voltage activated, and I created the MOD file based on my experimental data. So when I want to insert this mechanism into my reconstructed cell, it un...
by finesniper
Thu Jan 14, 2016 12:12 pm
Forum: Adding new mechanisms and functions to NEURON
Topic: Making a delay in the activation of an ionic current
Replies: 1
Views: 4450

Making a delay in the activation of an ionic current

Hello! I am currently doing a model on reproducing the firing of my recordings from interneurons. The main concenpt of this model is to see, how A-type potassium channels creates a delay in the firing, with the appropriate kinetics. In my recordings, the current does not activate until 1-2 ms after ...