Search found 9 matches
- Sat Apr 29, 2017 5:48 am
- Forum: The GUI
- Topic: dt resolution and unexpected oscillations
- Replies: 14
- Views: 25489
Re: dt resolution and unexpected oscillations
followed your lead and found the additional updated channels (na12 and na16 from foutz et al) that i have been using. sadly the new channels have different kinetics so a straight substitution is not possible. will have to leave this for now and continue with fixed dt. thanks again.
- Thu Apr 27, 2017 4:48 pm
- Forum: The GUI
- Topic: dt resolution and unexpected oscillations
- Replies: 14
- Views: 25489
Re: dt resolution and unexpected oscillations
Hi ted,
this is fantastic news. I looked for updates but i didnt find them. i will test them post haste. cheers and thanks again.
this is fantastic news. I looked for updates but i didnt find them. i will test them post haste. cheers and thanks again.
- Sat Apr 22, 2017 5:28 am
- Forum: The GUI
- Topic: dt resolution and unexpected oscillations
- Replies: 14
- Views: 25489
Re: dt resolution and unexpected oscillations
Hi ted, just looking at the scope of this project and i suspect that a search for CVODE compatible mechanisms might take as long as i have to explore the model (a week or so). Accordingly i might just take this on the chin. I increased Atol stringency on a few runs and it seems to stabilize the solu...
- Thu Apr 20, 2017 5:35 am
- Forum: The GUI
- Topic: dt resolution and unexpected oscillations
- Replies: 14
- Views: 25489
Re: dt resolution and unexpected oscillations
looking at the mod files, i see they are built by Zach Mainen and Alain Destexhe in the mid 90s. thanks for your help.
- Wed Apr 19, 2017 5:17 pm
- Forum: The GUI
- Topic: dt resolution and unexpected oscillations
- Replies: 14
- Views: 25489
Re: dt resolution and unexpected oscillations
i am running nrn-7.4 on a Core2 vPro machine and windows 7 enterprise. i tested your recommended sequence with NEURONdemo and obtained the pop up window. not so lucky loading my own myelinated neuron. Clicking the use variable dt checks the box. Clicking the Atol scale tool button is acknowledged in...
- Wed Apr 19, 2017 2:57 pm
- Forum: The GUI
- Topic: dt resolution and unexpected oscillations
- Replies: 14
- Views: 25489
Re: dt resolution and unexpected oscillations
just checked with the Neuron book and daspk should work for me. i am running the extracellular mechanism to simulate myelin on the axon. just checking that the numerical method selection is operating correctly. when i open the dialog from the variable timestep window, i can select daspk but i cannot...
- Wed Apr 19, 2017 12:49 pm
- Forum: The GUI
- Topic: dt resolution and unexpected oscillations
- Replies: 14
- Views: 25489
Re: dt resolution and unexpected oscillations
OK works now. i must have attempted adjusting dt in the wrong way. unfortunately i still see the oscillation using 973 points plotted / ms so the only option seems to be finding daspk compatible channels or figuring out how to convert them. any pointers here?
thanks
thanks
- Wed Apr 19, 2017 5:11 am
- Forum: The GUI
- Topic: dt resolution and unexpected oscillations
- Replies: 14
- Views: 25489
Re: dt resolution and unexpected oscillations
thanks for your suggestions. would love to use daspk just because of the simulation time savings. unfortunately several of the ion channel mechanisms i obtained from modelDB are only compatible with the fixed time step. i cant read or script in hoc so i am unable to solve the problem. is there a con...
- Tue Apr 18, 2017 4:35 pm
- Forum: The GUI
- Topic: dt resolution and unexpected oscillations
- Replies: 14
- Views: 25489
dt resolution and unexpected oscillations
i have been testing a single neuron generated with cellbuilder, which includes an axon initia segment so i can explore the effect of changing ion channel densities on the max amplitude of back propagating action potentials (bAPs). i was intrigued by an unexpected oscillation in bAP amplitudes while ...